ALKALINITY P&T KIT
DIRECT READING TITRATOR, 0-200 ppm
CODE 4533-DR-01
QUANTITY CONTENTS CODE
100 Phenolphthalein Tablets T-2246-J
100 BCG-MR Indicator Tablets T-2311-J
60 mL *Alkalinity Titration Reagent B *4493DR-H
1 Test Tube, 5-10-15 mL, glass, w/cap 0778
1 Direct Reading Titrator, 0-200 Range 0382
*WARNING: Reagents marked with an * are considered to be potential health hazards.
To view or print a Material Safety Data Sheet (MSDS) for these reagents go to
www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail, phone or fax.
To order individual reagents or test kit components,
use the speci ed code number.
NOTE: Read the Direct Reading Titrator Instruction
Manual (1649) before proceeding. Each minor
division on the Titrator scale equals 4 ppm CaCO
3
.
PHENOLPHTHALEIN (P) ALKALINITY PROCEDURE
1. Fill test tube (0778) to 5 mL line with sample water.
2. Add one Phenolphthalein Tablet (T-2246). Cap and mix until tablet disintegrates.
If solution does not turn red, P Alkalinity is 0. If solution turns red, proceed to Step 3.
3. Fill the Direct Reading Titrator (0382) with *Alkalinity Titration Reagent B
(4493DR). Insert Titrator into center hole of test tube cap.
4. While gently swirling tube, slowly press plunger to titrate until red color disap-
pears. Read the test result directly from the scale where the large ring on the Titra-
tor meets the Titrator barrel. Record as ppm P Alkalinity as CaCO
3
.
EXAMPLE: Plunger tip is 3 minor divisions below line 80. The test result is 80
plus 12 (3 divisions x 4) equals 92 ppm.
5. If plunger tip reaches the bottom line on the Titrator scale (200 ppm) before the
color change occurs, re ll the Titrator and continue the titration. When recording
test result, be sure to include the value of original amount of reagent dispensed
(200 ppm).
NOTE: Do not move Titrator plunger after the P Alkalinity endpoint has been
obtained. The titration is continued in the T Alkalinity procedure.
TOTAL (T) ALKALINITY PROCEDURE
6. Being careful not to move plunger, remove Titrator and cap from test tube con-
taining sample that was titrated in Step 4.
7. Add one BCG-MR Tablet (T-2311). Cap and shake until tablet disintegrates.
Solution will turn green-blue.
WARNING! This set contains chemicals
that may be harmful if misused. Read
cautions on individual containers
carefully. Not to be used by children
except under adult supervision
Page view 0
1 2

Summary of Contents

Page 1 - ALKALINITY P&T KIT

ALKALINITY P&T KITDIRECT READING TITRATOR, 0-200 ppmCODE 4533-DR-01QUANTITY CONTENTS CODE100 Phenolphthalein Tablets T-2246-J100 BCG-MR Indicator

Page 2 - 64533-DR-01 12/11

8. Reinsert Titrator in cap and continue titration until color changes from green-blue to pink. Read the test result directly from the scale where th

Comments to this Manuals

No comments