AUX IL IARY PHOS PHO RUS TEST KIT
MODEL APT • CODE 7884
QUANTITY CONTENTS CODE
60 mL *Sulfuric Acid, 36% *7885-H
15 mL *Phenolphthalein Indicator, 1% *2246-E
120 mL *Sodium Hydroxide, 15% *7886-J
30 g *Ammonium Persulfate Reagent *6566-G
120 mL Deionized Water 5115PT-J
10 g Boiling Stones 7888-D
2 Pipets, 1 mL, plastic 0354
1 Spoon, 0.5 g, plastic 0698
1 Funnel 0459
2 Erlenmeyer Flasks, 125 mL, glass 0431
1 Filter paper, 100 sheets 0463
1 Graduated Cylinder, 50 mL, glass 0418
*WARNING: Reagents marked with a * are considered to be potential health
hazards. To view or print a Material Safety Data Sheet (MSDS) for these
reagents go to www.lamotte.com. To obtain a printed copy, contact LaMotte by
email, phone or fax.
To order individual reagents or test kit components, use the specified code
number.
All phosphorus determinations measure orthophosphate only. To
determine other forms of phosphorus in a sample, they must be separated
and converted to orthophosphate. The Auxiliary Phosphorus test
equipment is required to effect these separations and must be used in
conjunction with one of the standard phosphorus test kits such as Dual
Range Phosphate Kit (1-100 ppm PO
4
-3
, Code 3320-01), or Low Range
Phosphate Kit (0.05-1.0 ppm PO
4
-3
, Code 7416-01).
WARNING! This set contains chemicals
that may be harmful if misused. Read
cautions on individual containers
carefully. Not to be used by children
except under adult supervision
Comments to this Manuals